A fully-digital realtime SoC FPGA based phase noise analyzer with cross-correlation
2017
We report on a fully-digital and realtime operation of a phase noise analyzer using modern digital techniques with cross-correlation. With the advent of system on chip field-programmable gate arrays (SoC FPGAs) embedding hard core central processing unit, coprocessor and FPGA onto a single integrated circuit, the building of sensitive analysis devices for Time & Frequency research is made accessible at virtually no cost and benefits from reconfigurability. Used with high-speed digitizers we have successfully implemented a four-channel system whose preliminary results at 10 MHz shows a residual white noise floor < −185 dBrad2/Hz up to 5 MHz off the carrier, and flicker < −127 dBrad2/Hz using…
Development of hard x-ray photoelectron SPLEED-based spectrometer applicable for probing of buried magnetic layer valence states
2016
Abstract A novel design of high-voltage compatible polarimeter for spin-resolved hard X-ray photoelectron spectroscopy (Spin-HAXPES) went into operation at beamline BL09XU of SPring-8 in Hyogo, Japan. The detector is based on the well-established principle of electron diffraction from a W(001) single-crystal at a scattering energy of 103.5 eV. It's special feature is that it can be operated at a high negative bias potential up to 10 kV, necessary to access the HAXPES range. The polarimeter is operated behind a large hemispherical analyzer (Scienta R-4000). It was optimized for high transmission of the transfer optics. A delay-line detector (20 mm dia.) is positioned at the exit plane of the…
Non-contact breath sampling for sensor-based breath analysis
2019
Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a…
Microcentrifuge or Automated Hematological Analyzer to Assess Hematocrit in Exercise? Effect on Plasma Volume Loss Calculations
2016
The assessment of plasma volume loss (∆PV) induced by exercise can be estimated from changes in hematocrit (Htc) and hemoglobin (Hb), and it is essential when investigating the metabolic or biologic response to exercise of circulating biomarkers. We aimed to ascertain whether the estimation of ∆PV may differ when Hb and Htc are determined by automated hematological analyzer (AHA) versus manual methods. Twenty-five healthy male subjects performed a maximal running incremental exercise. Blood samples were taken before exercise, immediately after exercise, and after a 30-min recovery. Hb and Htc (Htc-AHA) were determined by an AHA. Htc was also determined by microcentrifugation (Htc-M). The ∆P…
Interaction of metal ions with D-glucobenzothiazoline: isolation and characterization of the resultant products
2002
Six different metal-ion complexes of D-glucobenzothiazoline were synthesized and characterized by analytical and spectral techniques. Formation of different types of species (ML and ML2) were observed with Cu2+, Ag+, Cd2+, Hg2+, and Zn2+ ions. Existence of an anomeric mixture in the case of the Cu2+ complex is identified from the EPR spectra, and the results were further supported by the simulated spectra. The structures were proposed based on different studies.
Artifacts and Errors in Cross-Spectrum Phase Noise Measurements : Invited lecture
2021
Inserting an attenuator between the oscillator under test and the phase noise analyzer, one expects that the white phase noise increases monotonically with the attenuation. By contrast, we observe that with some oscillators the white noise has sharp minimum for a given value of the attenuation, which clearly indicates problem. With other oscillators, it increases monotonically with the attenuation, but the values are not consistent with the thermal energy introduced by the attenuator. In both cases artifacts are present, which takes the form of a sharp notch in the spectrum, occurring where the white FM noise crosses the white PM noise. Such anomalous behavior is the tip of the iceberg, and…
A PC-based low cost impedance and gain-phase analyzer
2008
Abstract In this paper, we present a practical and inexpensive impedance/gain-phase analyzer (IGPA), which is very useful in the design of electronic circuits. This instrument allows the Bode diagram of any network or electronic circuit with an input and an output to be obtained, even though this implementation was not previously known. It can also obtain the module and phase diagrams of any impedance separately. The device under test (DUT) is connected to a personal computer (PC) via the parallel port by means of an electronic circuit implemented for this purpose. The results are shown on the screen of the PC and can be accessible for use in any further operation. The instrument operates i…
A Freely Available Morphological Analyzer, Disambiguator and Context Sensitive Lemmatizer for German
1998
In this paper we present Morphy, an integrated tool for German morphology, part-of-speech tagging and context-sensitive lemmatization. Its large lexicon of more than 320,000 word forms plus its ability to process German compound nouns guarantee a wide morphological coverage. Syntactic ambiguities can be resolved with a standard statistical part-of-speech tagger. By using the output of the tagger, the lemmatizer can determine the correct root even for ambiguous word forms. The complete package is freely available and can be downloaded from the World Wide Web.
Statistical analysis of noise levels in urban areas
1991
Abstract Environmental noise measurements have been carried out during recent years in different cities and locations of Spain. The noise levels have been continuously sampled over 24 h periods using a noise level analyzer. The data contained in this paper represent a total of 4200 measurement hours. All the information has been used to investigate the time patterns of the noise levels under a wide range of different conditions and to study the relationships between several noise descriptors in urban areas.
Time-of-flight photoelectron momentum microscopy with 80–500 MHz photon sources: electron-optical pulse picker or bandpass pre-filter
2021
Journal of synchrotron radiation 28(6), 1891 - 1908 (2021). doi:10.1107/S1600577521010511